AS & A Level Physics · Area 2 · A Level Content

Alternating Currents

An alternating current reverses direction in a regular cycle, and its period, frequency and peak value describe the waveform. This topic covers the equation x = x0 sin omega t, the mean power in a resistive load, root-mean-square values, half-wave and full-wave rectification, smoothing with a capacitor, and the transformers that let the National Grid transmit at high voltage.

Not started

Syllabus coverage

  • Understand and use the terms period, frequency and peak value as applied to an alternating current or an alternating voltage
  • Use equations of the form x = x0 sin omega t representing a sinusoidally alternating current or voltage
  • Recall and use the fact that the mean power in a resistive load is half the maximum power for a sinusoidal alternating current
  • Distinguish between root-mean-square (r.m.s.) and peak values, and recall and use I r.m.s. = I0 / sqrt(2) and V r.m.s. = V0 / sqrt(2) for a sinusoidal alternating current
  • Distinguish graphically between half-wave and full-wave rectification
  • Explain the use of a single diode for the half-wave rectification of an alternating current
  • Explain the use of four diodes (a bridge rectifier) for the full-wave rectification of an alternating current
  • Analyse the effect of a single capacitor in smoothing, including the effect of the values of capacitance and of the load resistance
  • Understand the practical and economic advantages of the transmission of power by electricity, including the use of transformers to step the voltage up for transmission and down for use, with Vp / Vs = Np / Ns = Is / Ip and efficiency = (Vs Is / Vp Ip) x 100%

Part of the AS & A Level Physics syllabus 9702.

Alternating voltage and the mean power in a resistorV r.m.s. is the steady direct voltage that would give the same mean power in a resistor. For a sine wave V r.m.s. = V0 / sqrt(2) =0.707 x V0.Alternating voltagevoltage V (V)3250-32500.010.020.030.04time t (s)T = 0.020 sf = 1 / T = 50 Hzpeak value V0 = 325 VV r.m.s. = 230 VMean power in a resistorpower P (W)1000500000.010.020.030.04time t (s)mean power = 500 WP = P0 sin^2(2 pi f t)P0 = V0^2 / R = 1000 Wthe power peaks twice per cycle of the voltageThe peak value V0 and the period T are read from the waveform. The frequency f = 1 / T, and for a low-frequency supply in the UnitedKingdom T = 0.020 s, so f = 50 Hz.The r.m.s. value is the value of the steady direct voltage that gives the same mean power in a resistor: V r.m.s. = V0 / sqrt(2) =0.707 x V0, so 325 V peak gives 230 V r.m.s.Because the voltage is squared, the power never goes negative and it swings between 0 and P0 = V0^2 / R twice every cycle. The meanpower is P0 / 2.The mean power is also P = V r.m.s. x I r.m.s. = I r.m.s.^2 R = V r.m.s.^2 / R, so the mean of an alternating current is found fromits r.m.s. values, not its peak values.
A sinusoidal alternating voltage plotted against time, with the peak value V0, the peak-to-peak value 2V0 and the period T marked, together with the root-mean-square value V0 / sqrt(2). The r.m.s. value is the steady direct voltage that would deliver energy to a resistor at the same average rate as the alternating supply, so it is smaller than the peak but is the value used in every power calculation.

Alternating currents: period, frequency and peak value

An alternating current is a current that repeatedly reverses its direction, flowing first one way and then the other in a regular cycle. The voltage that drives it, the alternating voltage, does exactly the same: it swings positive and then negative about zero. The sinusoidal case matters most, because the e.m.f. produced by an a.c. generator is very nearly a sine wave, and the whole of the public electricity supply is generated and distributed as a sinusoid.

The period T is the time taken for one complete cycle, from a point on the waveform to the identical point on the next cycle, and it is measured in seconds. The frequency f is the number of complete cycles in one second, measured in hertz (Hz). The two are reciprocals: f = 1 / T and T = 1 / f. The mains supply in the United Kingdom alternates at 50 Hz, so its period is T = 1 / 50 = 0.020 s, which is 20 ms. Each cycle contains two half cycles of 10 ms, one positive and one negative.

The peak value I0 or V0 is the maximum value reached in either direction, and it is also called the amplitude. It is the value that decides whether insulation survives, because at the peak of the cycle the potential difference across the insulation is at its greatest. The peak-to-peak value is twice the peak value, and mixing the two up is a common error: a supply quoted as 230 V has a peak value of 325 V and a peak-to-peak value of 650 V.

The mean value of a sinusoidal current over one complete cycle is zero, because the positive half cycle cancels the negative half cycle exactly. That is why a moving-coil ammeter, which responds to the mean value, reads zero when it is connected to an alternating supply, and why such a meter has to have a rectifier built into it before it can measure alternating current at all.

  • Period T: the time for one complete cycle, T = 1 / f, measured in seconds (s).
  • Frequency f: the number of complete cycles per second, f = 1 / T, measured in hertz (Hz).
  • Peak value I0 or V0: the maximum value reached in either direction, sometimes called the amplitude.
  • United Kingdom mains is 50 Hz, so T = 1 / 50 = 0.020 s = 20 ms, with half cycles of 10 ms.
  • The mean of a sinusoidal alternating current over a complete cycle is zero.
Peak-to-peak is twice the peak. A 230 V mains supply has a peak value of 230 x sqrt(2) = 325 V and a peak-to-peak value of 650 V.

Writing an alternating quantity as x = x0 sin omega t

Any sinusoidally varying quantity can be written as x = x0 sin omega t, where x is the instantaneous value at time t, x0 is the peak value and omega is the angular frequency. The angular frequency is related to the frequency by omega = 2 pi f, and it is measured in radians per second (rad s-1). Because one complete cycle is 2 pi radians, a frequency of 50 Hz corresponds to an angular frequency of 2 pi x 50 = 314 rad s-1.

The sine form comes from the generator itself. A coil rotating at a constant rate in a uniform magnetic field sweeps through the field so that the flux linkage varies with the cosine of the angle turned through, and by Faraday's law the induced e.m.f. is proportional to the rate of change of that flux linkage, so the e.m.f. varies with the sine of the angle. A constant rotation rate therefore gives a sinusoidal e.m.f. of constant peak value, and the peak value is fixed by the speed of rotation, the strength of the field and the number of turns on the coil.

Worked example. The United Kingdom mains supply is quoted as 230 V, which is a root-mean-square value, so its peak value is 230 x sqrt(2) = 325 V and its angular frequency is 2 pi x 50 = 314 rad s-1. The instantaneous voltage is therefore v = 325 sin(314 t), with v in volts and t in seconds. At t = 2.0 ms, omega t = 314 x 2.0 x 10-3 = 0.63 rad, so v = 325 sin(0.63) = 325 x 0.59 = 190 V.

Check the value at the quarter points of one cycle, because that is the quickest way to show you understand what the equation means. At t = 5.0 ms, which is one quarter of a 20 ms period, sin(pi / 2) = 1 and the voltage is at its peak, 325 V. At t = 10 ms, half way through the cycle, sin(pi) = 0 and the voltage is zero. At t = 15 ms, the voltage is at its negative peak, -325 V, and at 20 ms the cycle begins again.

  • x = x0 sin omega t: x is the instantaneous value, x0 the peak value and omega the angular frequency.
  • omega = 2 pi f, measured in rad s-1; a 50 Hz supply gives omega = 314 rad s-1.
  • v = 325 sin(314 t) describes the United Kingdom mains supply, with v in volts and t in seconds.
  • At t = 5.0 ms the voltage is at its peak, at 10 ms it is zero and at 15 ms it is at its negative peak.
One cycle is 2 pi radians of omega t, so the cycle time is T = 2 pi / omega = 1 / f. Confirm that the numbers agree before you trust them.

Power in a resistive load: why the mean power is half the maximum power

The instantaneous power delivered to a resistor is P = I^2 R, or equally P = V^2 / R. Because the current is squared, the power is positive whether the current is positive or negative, so energy is transferred to the resistor right through the cycle, in both halves of it. The resistor heats up just as it would on a direct current of the same size, which is why a filament lamp on an alternating supply glows steadily instead of flickering.

The power is far from constant. It reaches a maximum of P0 = I0^2 R at the instant the current reaches its peak value, and it falls to zero twice in every cycle, as the current passes through zero. What heats the resistor is the mean power, and for a sine wave the mean value of sin^2(omega t) over a complete cycle is 1/2. The mean power is therefore half the maximum power: mean power = (1/2) I0^2 R.

A numerical check makes the result clear. A current of peak value 4.0 A flows in a resistor of resistance 25 ohm. The maximum power is 4.0^2 x 25 = 400 W. The mean value of the square of the current is 4.0^2 / 2 = 8.0 A2, so the mean power is 8.0 x 25 = 200 W, exactly half of 400 W. Using the r.m.s. current gives the same answer at once: I r.m.s. = 4.0 / sqrt(2) = 2.83 A, and I r.m.s.^2 R = 2.83^2 x 25 = 200 W.

The same reasoning applies to voltage: mean power = (1/2) V0^2 / R = V r.m.s.^2 / R. Notice that the mean power is not found by putting the mean values of current and voltage into P = VI, because those means are both zero. It is the square that is averaged first, and that is the whole point of the root-mean-square value.

  • Instantaneous power P = I^2 R, positive in both halves of the cycle because the current is squared.
  • Maximum power P0 = I0^2 R, reached only at the peaks of the waveform.
  • The mean value of sin^2(omega t) over one cycle is 1/2, so the mean power is (1/2) I0^2 R.
  • A peak current of 4.0 A in a 25 ohm resistor gives 400 W at the peaks and 200 W on average.
QuantityValue for this example
Peak current I04.0 A
Maximum power I0^2 R4.0^2 x 25 = 400 W
Mean square current I0^2 / 28.0 A2
Mean power8.0 x 25 = 200 W
r.m.s. current I0 / sqrt(2)2.83 A, giving 2.83^2 x 25 = 200 W
Never use the peak value in a power calculation for an alternating supply. The heating effect is set by the mean power, which is half the maximum power for a sine wave.

Root-mean-square values and what they are for

Because the mean of an alternating current is zero, a different kind of average is needed to describe its heating effect. The root-mean-square value of an alternating current is defined as the value of the direct current that would dissipate energy at the same mean rate in the same resistor. The name says how it is calculated: square the current, take the mean of the square, then take the square root. For a sine wave this gives the peak value divided by the square root of 2.

I r.m.s. = I0 / sqrt(2) and V r.m.s. = V0 / sqrt(2). Dividing by the square root of 2 is the same as multiplying by 0.707, so the r.m.s. value is about 71 per cent of the peak value. The United Kingdom mains supply is 230 V r.m.s. at 50 Hz, so the peak voltage is 230 x sqrt(2) = 325 V and the peak-to-peak voltage is 650 V.

Use r.m.s. values in every power and energy question, because that is what they were invented for: mean power = V r.m.s. I r.m.s. = I r.m.s.^2 R = V r.m.s.^2 / R. Use the peak value in questions about insulation, breakdown and peak electric field, because that is the instant at which the material is most highly stressed. Reading the wrong one off a meter is the classic mistake in this topic.

An alternating voltmeter or ammeter is designed to read r.m.s. values for a sine wave, usually by rectifying the current inside the instrument and then scaling the movement. That calibration only holds for a sinusoidal waveform: for a square wave, a triangle wave or a distorted supply, a simple meter gives a reading that has little to do with the true r.m.s. value, which is why true r.m.s. instruments exist. Remember too that the r.m.s. value is not the mean value, which is zero, and it is not half the peak value either.

  • Definition: the r.m.s. value of an alternating current is the direct current that would dissipate energy at the same mean rate in the same resistor.
  • I r.m.s. = I0 / sqrt(2) and V r.m.s. = V0 / sqrt(2), so the r.m.s. value is 0.707 times the peak value.
  • Mean power = V r.m.s. I r.m.s. = I r.m.s.^2 R = V r.m.s.^2 / R.
  • 230 V r.m.s. mains has a peak value of 325 V and a peak-to-peak value of 650 V.
  • Meters calibrated to read r.m.s. are only correct for a sinusoidal waveform.
Define r.m.s. by its heating effect, then use it in every power calculation. Peak values belong in insulation and breakdown questions.

Rectification: half-wave and full-wave

Rectification is the conversion of an alternating current into a direct current, meaning a current that flows in one direction only. The component that does the work is the diode, which conducts when it is forward biased with the anode positive with respect to the cathode, and does not conduct when it is reverse biased. A diode is therefore a one-way valve for current, and that single property is the whole basis of rectification.

Half-wave rectification uses one diode in series with the load. The diode conducts during the half cycle in which it is forward biased, so current flows through the load; during the other half cycle the diode is reverse biased and no current flows at all. The output is unidirectional, but it arrives in separate pulses, one for each cycle of the supply, with a gap at zero volts lasting a whole half cycle between one pulse and the next. The mean output is low, and the gaps make the output hard to smooth.

Full-wave rectification uses four diodes connected as a bridge rectifier. During one half cycle two of the diodes are forward biased and conduct, carrying current through the load in one direction; during the other half cycle the other two conduct and push current through the load in the same direction again. The load therefore receives a pulse in every half cycle, so a 50 Hz supply produces 100 pulses per second, and the mean power delivered to the load is twice what the same supply gives through a half-wave rectifier.

On an oscilloscope the two outputs are unmistakably different. The half-wave trace shows a rounded pulse, then a flat section at zero for the same length of time, then the next pulse: two humps in the time of two supply cycles. The full-wave trace shows humps one after another with no gaps, and at twice the supply frequency: two humps in the time of one supply cycle. Both outputs have the same peak value as each other, a little below the peak of the input because of the forward voltage drop of the conducting diodes: about 0.7 V is lost in a single-diode circuit and about 1.4 V in a bridge, where two diodes carry the current in series.

FeatureHalf-wave (one diode)Full-wave (bridge of four diodes)
Output pulses per supply cycleOneTwo, one for each half cycle
Gap in the outputA full half cycle at zero voltsNone: the next pulse begins immediately
Output frequency for a 50 Hz supply50 Hz100 Hz
Peak output voltagePeak of the input less about 0.7 VPeak of the input less about 1.4 V
Mean power in the loadHalf the full-wave valueTwice the half-wave value for the same peak
Half-wave: one diode, one pulse per cycle and gaps. Full-wave: four diodes in a bridge, a pulse every half cycle, no gaps and twice the mean power.

Smoothing: the effect of a capacitor across the load

A rectified output is unidirectional but nowhere near steady: it rises and falls, and the variation about the mean is called the ripple. Connecting a single capacitor in parallel with the load resistor smooths the output, turning a series of pulses into something much closer to a steady direct voltage.

The capacitor works in two stages. While the rectifier output is rising towards its peak, the capacitor charges and the voltage across it follows the output, while the current that charges it also flows through the load. As soon as the rectifier output begins to fall, the voltage on the capacitor is higher than the output voltage, the diodes stop conducting, and the capacitor discharges through the load resistor instead. The load therefore keeps drawing current while the rectifier is, in effect, doing nothing, and the output voltage falls only a little before the next pulse arrives and recharges the capacitor.

How well this works depends on the time constant RC of the capacitor and the load, compared with the time between pulses. If RC is much greater than the interval between pulses, the capacitor discharges only a little in each interval and the output is nearly steady; if RC is small, the voltage sags a long way and the ripple is large. After full-wave rectification of a 50 Hz supply the pulses arrive every 10 ms, so a capacitor of 4700 microfarads (4.7 x 10-3 F) with a load of 100 ohm gives RC = 0.47 s, nearly fifty times the interval between pulses, and the output is very steady. Increasing the capacitance, or increasing the load resistance, reduces the ripple; reducing either one makes it worse.

The capacitor also raises the average output, because the load is supplied at a voltage near the peak for most of each cycle instead of at the mean of the pulses, so an unregulated supply with a large smoothing capacitor gives a steady output close to the peak value of the rectified waveform. The price is a large surge of current through the diodes every time the capacitor recharges, together with a large electrolytic capacitor that takes up space and must be connected the right way round.

  • The capacitor charges to the peak of the rectified output and then discharges through the load resistor when the output falls.
  • Smoothing works because the capacitor supplies the load during the gaps between pulses.
  • The ripple is small when the time constant RC is much greater than the time between pulses.
  • Increasing the capacitance or increasing the load resistance increases RC and reduces the ripple.
  • 4700 microfarads with a 100 ohm load gives RC = 0.47 s, far longer than the 10 ms between pulses of a full-wave 50 Hz supply.
Smoothing is a race between the time constant RC and the time between pulses. Make RC large compared with the ripple period and the output is almost steady direct current.

Transformers: turns ratio, current ratio and efficiency

A transformer changes the size of an alternating voltage. It consists of two coils, the primary and the secondary, wound on a laminated soft iron core. An alternating current in the primary sets up a changing magnetic flux in the core, the core carries almost all of that flux to the secondary, and the changing flux linkage induces an alternating e.m.f. in the secondary by Faraday's law. The core is laminated, made of thin sheets insulated from one another, to break up the eddy currents that would otherwise circulate in it and waste energy.

Because the same flux passes through every turn of both coils, the e.m.f. induced in each turn is the same, so the voltages are in the ratio of the numbers of turns: Vp / Vs = Np / Ns. This ratio of turns is the turns ratio. If the secondary has more turns than the primary the transformer is a step-up transformer and the voltage rises; if it has fewer turns it is a step-down transformer and the voltage falls. The frequency is unchanged, because a transformer cannot alter the frequency of a supply.

For an ideal transformer, which wastes no energy, the power delivered to the secondary equals the power taken from the primary: Vp Ip = Vs Is. Combining this with the turns ratio gives Np / Ns = Is / Ip, so a transformer that steps the voltage up steps the current down in the same proportion, and the other way round. A real transformer is less than 100 per cent efficient, so the secondary current is a little below the ideal value, and the efficiency is calculated as efficiency = (Vs Is / Vp Ip) x 100%. The losses are resistive heating in the windings, eddy currents and hysteresis in the core, and a little flux leakage.

Worked example. A step-down transformer for a 12 V lighting circuit has 1150 turns on the primary and is connected to the 230 V mains. The number of turns on the secondary is Ns = Np Vs / Vp = 1150 x 12 / 230 = 60 turns. If the secondary supplies 4.0 A, an ideal transformer would draw Ip = Is Ns / Np = 4.0 x 60 / 1150 = 0.21 A from the mains, and a real transformer with an efficiency of 95 per cent draws 0.22 A. Note that the transformer works only on alternating current: a steady direct current in the primary gives a steady flux, no changing flux linkage and therefore no induced e.m.f. in the secondary at all.

  • A transformer is two coils on a laminated soft iron core, working by mutual induction.
  • Turns ratio: Vp / Vs = Np / Ns. More turns on the secondary means a step-up transformer.
  • Ideal transformer: Vp Ip = Vs Is, so Np / Ns = Is / Ip.
  • Efficiency = (Vs Is / Vp Ip) x 100%, reduced by resistance, eddy currents, hysteresis and flux leakage.
  • A transformer cannot work on steady direct current, because there is no changing flux.
Step the voltage up and the current falls in the same ratio. A transformer needs a changing current, which is one reason the whole grid is an alternating one.
The transformer and the National GridTwo coils wound on a laminated iron core. An alternating current in the primary makes a changing flux in the core, which induces analternating e.m.f. in the secondary.A step-down transformerlaminatediron corea.c. inputoutput to the loadprimarysecondaryThe transformer equationVp / Vs = Np / Nsvoltage ratio = turns ratioNp = 1000 turns, Ns = 50 turns, Vp = 230 VNs / Np = 50 / 1000 = 1 / 20, so this steps the voltage downVs = Vp x Ns / Np = 230 / 20 = 11.5 Vinput power = Ip x Vp = 0.5 x 230 = 115 Wif the transformer were 100% efficient, Is = 115 / 11.5 = 10 Aso the voltage falls by a factor of 20 and the current rises by 20efficiency = useful output power / input power x 100%Why the National Grid transmits at a very high voltagepower station25 kVstep-up400 kV cablesstep-downtown230 VPower sent: P = 100 MW. Resistance of the cables: R = 1.0 ohm.At 400 kV: I = P / V = 100 x 10^6 / 400 x 10^3 = 250 Apower wasted as heat = I^2 R = 250^2 x 1.0 = 62.5 kWAt 25 kV: I = 100 x 10^6 / 25 x 10^3 = 4000 Apower wasted as heat = I^2 R = 4000^2 x 1.0 = 16 MWSixteen times the current wastes 256 times the energy,so the grid steps the voltage up before it transmits the power.A transformer works only with alternating current: a steady current gives a steady flux, so no e.m.f. is induced in the secondary,however many turns it has.For an ideal transformer Ip x Vp = Is x Vs, so if the voltage is stepped up by a factor k the current is stepped down by the samefactor. Real transformers lose energy in the resistance of the windings, in eddy currents in the core, and by magnetising anddemagnetising the core - the laminations cut the eddy currents.
A step-down transformer: an alternating current in the primary coil produces a changing magnetic flux in the laminated iron core, the flux links the secondary coil, and a smaller alternating e.m.f. is induced in it because the secondary has fewer turns than the primary.

The National Grid: why power is transmitted at high voltage

The National Grid carries electrical power from power stations to the places where it is used. Power stations in the United Kingdom generate at about 25 kV, the grid transmits at 400 kV and 275 kV, and the voltage is stepped down in substations to 132 kV, 33 kV and 11 kV before it finally reaches homes and offices at 230 V. Transformers at every stage make this possible, and that is one reason the supply is alternating.

The reason for transmitting at a high voltage is the power wasted heating the cables. The power carried is P = VI, and the power wasted in the cables is I^2 R, where R is the total resistance of the conductors on the route. For a fixed transmitted power, raising the transmission voltage lowers the current in proportion, and the wasted power falls with the square of the current. Transmitting 200 MW through cables of total resistance 1.0 ohm needs 8000 A at 25 kV, which wastes 8000^2 x 1.0 = 64 MW, nearly a third of the power generated. At 400 kV the current is only 500 A and the loss is 500^2 x 1.0 = 250000 W, which is 0.25 MW. Raising the voltage by a factor of 16 has cut the waste by a factor of 256.

There is a second, economic advantage. For the same current density a smaller current needs a smaller cross-sectional area of conductor, so the cables can be thinner and lighter and less aluminium is needed, which means cheaper pylons and conductors. The saving in conductor material is a large part of the reason the grid is designed the way it is.

The voltage cannot be raised indefinitely, and evaluating the compromise is a standard examination task. Higher voltages need thicker insulation and greater clearance between the conductors and from the ground and buildings, because air breaks down and corona discharge begins when the electric field around a conductor becomes strong enough. The transformers and switchgear needed at very high voltage are themselves expensive, and the pylons must be taller. In practice 400 kV is close to the economic optimum for overhead lines on land.

For very long submarine cables, high-voltage direct current (h.v.d.c.) is sometimes used instead, for example on the cross-Channel link between England and France. A long alternating cable behaves as a capacitor, and the charging current that flows because of that cable capacitance is a loss that grows with the length of the cable; with direct current there is no charging current, so the cable can carry more useful power. At each end of such a link the alternating supply is rectified to direct current and then converted back to alternating current by power electronic converters.

  • Power stations generate at about 25 kV, the grid transmits at 400 kV and 275 kV, and substations step the voltage down to 230 V for use.
  • P = VI, so for a fixed power a higher voltage means a smaller current.
  • Cable losses are I^2 R, so raising the transmission voltage cuts the wasted power by the square of the voltage rise.
  • 200 MW at 25 kV wastes 64 MW in 1.0 ohm of cable, while the same power at 400 kV wastes only 0.25 MW.
  • A smaller current needs thinner, cheaper conductors, and the voltage is limited by insulation, clearance and cost.
  • Very long submarine cables use h.v.d.c. instead, because an alternating cable draws a large charging current.
Transmit at high voltage, use at low voltage. Transformers change the voltage between the two, and it is the alternating supply that lets them do it.

Key terms you must be able to define

Alternating current
A current that repeatedly reverses its direction, flowing first one way and then the other in a regular cycle; the alternating voltage that drives it does the same, and the public supply in the United Kingdom is a sinusoid of frequency 50 Hz.
Period and frequency
The period T is the time taken for one complete cycle and the frequency f is the number of complete cycles per second; they are reciprocals, f = 1 / T, with T in seconds and f in hertz (Hz). A 50 Hz supply has a period of 0.020 s.
Peak value
The maximum value reached by an alternating current or voltage in either direction, written I0 or V0 and sometimes called the amplitude; the peak-to-peak value is twice the peak value.
Root-mean-square value
The value of the direct current or voltage that would dissipate energy at the same mean rate in the same resistor; for a sinusoidal supply I r.m.s. = I0 / sqrt(2) and V r.m.s. = V0 / sqrt(2), and r.m.s. values are the ones used in power calculations.
Mean power
The average rate at which energy is transferred to a resistive load over a complete cycle; for a sinusoidal supply it is half the maximum power, so mean power = (1/2) I0^2 R = I r.m.s.^2 R.
Rectification
The conversion of an alternating current into a direct, unidirectional current, using one or more diodes, which conduct only when they are forward biased.
Bridge rectifier
Four diodes connected so that two conduct during each half cycle, giving full-wave rectification: the current through the load is in the same direction in both halves of the supply cycle, so there is a pulse every half cycle.
Smoothing
The reduction of the ripple in a rectified output by connecting a capacitor across the load, so that the capacitor charges to the peak of the output and then discharges through the load while the rectifier output falls.
Turns ratio
The ratio of the numbers of turns on the two coils of a transformer, Ns / Np, which equals Vs / Vp for an ideal transformer; since Vp Ip = Vs Is, it also fixes the ratio of the currents, so a step-up transformer steps the current down in the same proportion.

Applied to the real world

Cambridge sets 9702 in unfamiliar contexts - a fairground ride, a power station, a hospital scanner, a satellite, an astronomical observatory. Use these as models for how to apply the physics, then write your own.

In the laboratory

A cathode-ray oscilloscope is used to measure the peak voltage and the period of the output of a signal generator. With the time base off the trace is a vertical line whose length is the peak-to-peak voltage, and with the time base on the waveform is displayed against a calibrated scale. The height of a peak in divisions is multiplied by the y-gain in volts per division to give the peak voltage, and the time for one complete cycle read from the time base gives the period and hence the frequency. If an alternating voltmeter is connected to the same supply it reads the r.m.s. value, which for a 2.0 V peak sine wave is 2.0 / sqrt(2) = 1.4 V.

In engineering

The National Grid transmits at 400 kV and 275 kV because the power wasted in the cables is I^2 R. Transmitting 200 MW through cables of total resistance 1.0 ohm at 25 kV needs a current of 8000 A and wastes 64 MW, nearly a third of the power generated, while the same power at 400 kV needs only 500 A and wastes 250000 W, which is 0.25 MW. Step-up transformers at the power station raise the voltage and step-down transformers in substations lower it again to 132 kV, 33 kV and finally 230 V at the point of use.

At home

A laptop power supply takes 230 V r.m.s. alternating current, whose peak value is 325 V, rectifies it and smooths it with a capacitor, then switches the resulting direct voltage rapidly on and off to drive a small high-frequency transformer. The high frequency is chosen deliberately: a 50 Hz transformer able to carry 65 W would need a large, heavy iron core, whereas at tens of kilohertz the same job is done by a transformer the size of a matchbox. The output is then rectified and smoothed again to give a steady 19 V direct supply, and the efficiency of the whole unit is around 85 per cent.

On the road

A car alternator generates an alternating voltage as its rotor turns, but the 12 V battery can only be charged by a current flowing in one direction. A bridge rectifier built into the alternator converts the alternating output into direct current, with two of its six diodes conducting on each half cycle, and the output is then regulated to about 14 V. The battery itself acts as a large smoothing component, holding the voltage steady between the pulses of the rectified waveform.

In medicine

A hospital X-ray generator uses a step-up transformer to produce the very high direct voltage, typically between 40 kV and 150 kV, that is applied across the X-ray tube. The transformer secondary has far more turns than the primary, and the alternating high voltage it produces is rectified to direct current before being applied to the tube, because the tube must always have the anode positive relative to the cathode. The whole assembly is immersed in oil, which insulates the secondary winding and carries away the heat produced by the losses.

Flashcards

Click a card to flip it. Mark honestly — the tracker uses this.

Q1Define the period and the frequency of an alternating supply and give the relationship between them.
The period T is the time taken for one complete cycle; the frequency f is the number of complete cycles per second. They are reciprocals, f = 1 / T and T = 1 / f, with T in seconds and f in hertz. A 50 Hz supply has a period of 0.020 s.
Q2What is the peak value of an alternating voltage, and how does it relate to the peak-to-peak value?
The peak value V0 is the maximum value reached in either direction, also called the amplitude. The peak-to-peak value is twice the peak value, 2V0.
Q3Write the equation of a sinusoidal alternating voltage and explain every symbol.
v = V0 sin omega t, where v is the instantaneous voltage, V0 the peak value, omega the angular frequency (omega = 2 pi f, in rad s-1) and t the time in seconds.
Q4What is the angular frequency of the 50 Hz mains supply?
omega = 2 pi f = 2 pi x 50 = 314 rad s-1. One complete cycle corresponds to 2 pi radians, so the cycle takes 2 pi / omega = 0.020 s.
Q5How are the mean power and the maximum power in a resistive load related for a sinusoidal alternating current?
The mean power is half the maximum power: mean power = (1/2) I0^2 R, while the maximum is I0^2 R. It follows because the mean value of sin^2(omega t) over a complete cycle is 1/2.
Q6Define the root-mean-square value of an alternating current.
The value of the direct current that would dissipate energy at the same mean rate in the same resistor. Square the current, average the square and take the square root.
Q7Give the relationship between the r.m.s. and peak values of a sinusoidal current and voltage.
I r.m.s. = I0 / sqrt(2) and V r.m.s. = V0 / sqrt(2), which is 0.707 times the peak value in each case.
Q8What is the peak value of the 230 V mains supply, and what is its peak-to-peak value?
V0 = 230 x sqrt(2) = 325 V, so the peak-to-peak value is 2 x 325 = 650 V. The 230 V figure is the r.m.s. value.
Q9Why must the supply be alternating for a transformer to work?
The e.m.f. in the secondary is induced by a changing magnetic flux. A steady direct current produces a steady flux, so the flux linkage does not change and no e.m.f. is induced, however many turns the coils have.
Q10State the turns ratio relationship for an ideal transformer and the relationship between the currents.
Vp / Vs = Np / Ns, and since Vp Ip = Vs Is it follows that Np / Ns = Is / Ip. A step-up transformer raises the voltage and lowers the current in the same ratio.
Q11How is the efficiency of a transformer calculated, and where does the lost energy go?
Efficiency = (Vs Is / Vp Ip) x 100%, the power delivered to the secondary divided by the power supplied to the primary. The losses are resistive heating in the windings, eddy currents and hysteresis in the core, and flux leakage.
Q12What does a diode do, and what is the difference between half-wave and full-wave rectification?
A diode conducts only when it is forward biased. One diode gives half-wave rectification, with one pulse per cycle and a gap at zero volts between pulses; four diodes in a bridge give full-wave rectification, with a pulse every half cycle, no gaps and twice as many pulses per cycle.
Q13How does a capacitor across the load smooth a rectified output?
It charges to the peak of the rectified output and then discharges through the load resistor while the rectifier output falls, keeping the current flowing until the next pulse. Increasing the capacitance or the load resistance increases the time constant RC and reduces the ripple.
Q14Why is electrical power transmitted at high voltage along the National Grid?
Because P = VI, so for a fixed transmitted power a high voltage means a small current. The power wasted in the cables is I^2 R, so it falls with the square of the voltage rise, and the smaller current also allows thinner, cheaper conductors.
0 of 14 marked as known

Exam-style questions

9 questions, 32 marks. Write your answer, then reveal the mark scheme and tick each point you actually made. Answering honestly here is what makes the rest of the site useful.

StateAO11 mark
State what is meant by the period of an alternating current.

Mark scheme — tick each point you actually made

Examiner tip: One mark, one idea: a time for one complete cycle. The time between the peaks of a trace is only half of that if the trace has been drawn for two cycles, so say one complete cycle in words.
CalculateAO23 marks
A sinusoidal alternating voltage has a frequency of 50 Hz and a peak value of 325 V. (a) Calculate the period of the supply. (b) Calculate the root-mean-square value of the voltage. (c) The supply is connected across a resistor that dissipates a mean power of 1.0 kW. Calculate the resistance of the resistor.

Mark scheme — tick each point you actually made

Examiner tip: Use the r.m.s. voltage in the power calculation, not the peak. Starting from 325 V gives 325^2 / 1000 = 106 ohm, which is wrong by a factor of 2.
ExplainAO24 marks
A resistor carries a sinusoidal alternating current of peak value I0. Explain why the mean power dissipated in the resistor is half the maximum power.

Mark scheme — tick each point you actually made

Examiner tip: The mark comes from the squaring, not from the word average. Say that the current is squared first and then averaged, so the mean of the square is half the peak square.
Show thatAO23 marks
A sinusoidal alternating current of peak value 4.0 A flows in a resistor of resistance 25 ohm. Show that the mean power dissipated in the resistor is 200 W.

Mark scheme — tick each point you actually made

Examiner tip: A show that question needs the full working: write the equation, substitute the numbers and arrive at 200 W. The last mark is for landing on the given value with its unit W.
DescribeAO33 marks
A student uses a cathode-ray oscilloscope to measure the peak voltage of an alternating supply from a signal generator. Describe how the peak voltage is found, and explain why an alternating voltmeter connected to the same supply gives a smaller reading.

Mark scheme — tick each point you actually made

Examiner tip: Say which control is set and what is measured on the screen. The explanation of the voltmeter reading must name the r.m.s. value and the factor sqrt(2), not just say that the meters disagree.
ExplainAO23 marks
The output of a bridge rectifier is smoothed by connecting a capacitor across the load resistor. Explain how the capacitor smooths the output, and state and explain the effect of using a larger capacitance.

Mark scheme — tick each point you actually made

Examiner tip: Two stages, charge and discharge, and then the time constant. Saying only that the capacitor stores charge will not score the second mark, because the mark is for the discharge through the load supplying the current.
DescribeAO24 marks
A sinusoidal alternating voltage is connected across a load resistor first through a single diode and then through a bridge rectifier made from four diodes. Describe the difference between the two output waveforms seen on an oscilloscope, and explain how the four diodes of the bridge produce their output.

Mark scheme — tick each point you actually made

Examiner tip: Compare the two traces in the same sentence each time: number of pulses per cycle, gaps and frequency. Saying that full-wave is smoother without saying that it has twice as many pulses loses the third mark.
CalculateAO26 marks
A step-down transformer for a 12 V lighting circuit is connected to the 230 V mains supply. (a) The primary coil has 1150 turns. Calculate the number of turns on the secondary coil. (b) When four lamps are switched on, the secondary current is 4.0 A and the primary current is 0.22 A. Calculate the efficiency of the transformer.

Mark scheme — tick each point you actually made

Examiner tip: Write the turns ratio down before substituting, and keep the voltages the same way up on both sides. In part (b) calculate both powers before dividing, and quote the efficiency as a percentage to two significant figures.
ExplainAO25 marks
At a power station, a step-up transformer raises the voltage from 25 kV to 400 kV before the power is transmitted along the National Grid. The current in the primary coil is 8.0 kA. (a) Calculate the current in the secondary coil, assuming the transformer is ideal. (b) Explain why the transmission voltage is made as high as is practicable, and give one reason why it is not made very much higher.

Mark scheme — tick each point you actually made

Examiner tip: Use kilovolts and kiloamps as powers of ten in the working, and check the answer against the turns ratio: 400 / 25 = 16, so the current must fall by a factor of 16, from 8000 A to 500 A. In part (b) both halves are needed, the saving in lost power and the cost of the insulation.

Exam technique for this topic

  • Use r.m.s. values in every power and energy calculation, and peak values only in questions about insulation, breakdown or peak electric field. Putting the 325 V peak of the mains into a power calculation instead of the 230 V r.m.s. value inflates the answer by a factor of 2.
  • Remember that the mean of a sinusoidal current over a whole cycle is zero, while the mean of its square is half the peak squared. These are two different averages, and confusing them is what turns a correct method into a wrong answer.
  • In a transformer question write the relationships down before substituting: Vp / Vs = Np / Ns and Vp Ip = Vs Is. Give the efficiency as output power divided by input power, multiplied by 100 per cent, and round sensibly: 48 / 50.6 is 95 per cent, not 94.86166 per cent.
  • When you sketch or compare rectified waveforms, keep the peak value and the period the same as the input, and remember that a full-wave output has twice as many pulses in each cycle as a half-wave output and no gaps between them. Label the peak value and the time between pulses on your sketch.
  • For a smoothing question, compare the time constant RC with the time between pulses and say so explicitly. A large capacitance or a large load resistance gives a long RC, a slowly falling capacitor voltage and a small ripple, and naming which quantity you would change, and why, is worth a mark.
  • Give the unit with every answer and use the units as a check. Period is in seconds or milliseconds, frequency in Hz, angular frequency in rad s-1 and power in W. A frequency must never be substituted where an angular frequency is needed: convert it first with omega = 2 pi f, so 50 Hz becomes 314 rad s-1.

Why students lose marks here

A student wroteA student wrote: 'The mains voltage is 230 V, so the potential difference across the insulation reaches 230 V at the peak of the cycle.'
Why it loses marks230 V is the root-mean-square value, the value of direct voltage that would deliver energy to a resistor at the same average rate. The waveform actually rises to a peak that is sqrt(2) times larger, and it is the peak that the insulation has to withstand without breaking down.
The answer that scoresThe peak value is V0 = V r.m.s. x sqrt(2) = 230 x 1.41 = 325 V, and the peak-to-peak value is 650 V. Insulation, breakdown and peak electric field questions use the peak value; mean power and energy questions use the r.m.s. value, so mean power = V r.m.s.^2 / R.
Alternating voltage and the mean power in a resistorV r.m.s. is the steady direct voltage that would give the same mean power in a resistor. For a sine wave V r.m.s. = V0 / sqrt(2) =0.707 x V0.Alternating voltagevoltage V (V)3250-32500.010.020.030.04time t (s)T = 0.020 sf = 1 / T = 50 Hzpeak value V0 = 325 VV r.m.s. = 230 VMean power in a resistorpower P (W)1000500000.010.020.030.04time t (s)mean power = 500 WP = P0 sin^2(2 pi f t)P0 = V0^2 / R = 1000 Wthe power peaks twice per cycle of the voltageThe peak value V0 and the period T are read from the waveform. The frequency f = 1 / T, and for a low-frequency supply in the UnitedKingdom T = 0.020 s, so f = 50 Hz.The r.m.s. value is the value of the steady direct voltage that gives the same mean power in a resistor: V r.m.s. = V0 / sqrt(2) =0.707 x V0, so 325 V peak gives 230 V r.m.s.Because the voltage is squared, the power never goes negative and it swings between 0 and P0 = V0^2 / R twice every cycle. The meanpower is P0 / 2.The mean power is also P = V r.m.s. x I r.m.s. = I r.m.s.^2 R = V r.m.s.^2 / R, so the mean of an alternating current is found fromits r.m.s. values, not its peak values.
A sinusoidal alternating voltage showing the peak value V0, the peak-to-peak value 2V0 and the root-mean-square value V0 / sqrt(2), which for the 230 V mains supply is 325 V at the peak against 230 V r.m.s. Note that the r.m.s. value is neither the peak value nor half of it.
A student wroteA student wrote: 'A sinusoidal current of peak value 3.0 A flows in a 40 ohm resistor, so the power dissipated is 3.0^2 x 40 = 360 W.'
Why it loses marksThat is the maximum power, reached only at the two instants in each cycle when the current is at its peak value. What heats the resistor is the average rate of energy transfer over the whole cycle, and the current is below its peak for most of the time.
The answer that scoresThe mean power is half the maximum power: (1/2) x 3.0^2 x 40 = 180 W. Equivalently, the r.m.s. current is 3.0 / sqrt(2) = 2.1 A and I r.m.s.^2 R = 2.1^2 x 40 = 180 W. Both routes agree, and either is accepted.
A student wroteA student wrote: 'A step-down transformer can be used to reduce the steady 12 V output of a battery to 6 V for a small lamp.'
Why it loses marksA transformer works by mutual induction, so it needs a changing magnetic flux linking the secondary coil. The steady direct current from a battery produces a steady flux, so there is no changing flux linkage and no induced e.m.f. in the secondary at all, however many turns it has.
The answer that scoresA transformer only works on an alternating supply. To change the size of a steady direct voltage you must first convert it to alternating current with an inverter, which switches the direct current on and off electronically, then transform it and rectify the result back to direct current. That is exactly what a laptop power supply or a phone charger does, using a high-frequency transformer to keep the component small.
A student wroteA student wrote: 'Half-wave and full-wave rectification of the same sinusoidal supply give the same mean power in the load, because the peak value of the output is the same in both cases.'
Why it loses marksThe peak value is indeed the same, but a half-wave rectifier delivers energy to the load only during half of each cycle, so one entire half cycle contributes nothing at all. Averaging the square of the output over a whole cycle therefore halves the answer, and the heat produced is halved with it.
The answer that scoresFor full-wave rectification the mean of sin^2(omega t) over a cycle is 1/2, so the mean power is (1/2) I0^2 R. For half-wave rectification the load is connected for only half the time, so the mean square is a quarter of the peak square and the mean power is (1/4) I0^2 R, exactly half of the full-wave value. Full-wave rectification therefore delivers twice the power from the same supply and gives a much smoother output, with twice as many pulses per cycle.